(no subject)

Anna Porwit (anpo@mb.ks.se)
Mon, 20 Jan 1997 11:27:11 +0100

>
>Question for Clinical Flow People:
>
>
>What volume of bone marrow do you aspirate for flow. If you aspirate too
>much you get blood, not bone marrow. However, you want as much as possible
>from a single site. I had thought 1mL per site was maximum but was told
>today that 3 mL gives a good yield. Please share you specifications and I
>will summarize for those interested.
>
>
> Maryalice
>
>Maryalice Stetler-Stevenson
>Director Flow Cytometry Unit
>Laboratory of Pathology, NCI, NIH
>
>Hi!
We recommend 1,5 - 2ml BM in heparine tube with 1 ml NaCL. It works very
well, and we get enough materia even for our diagnostic program for acute
leukemia which (according to European Concerted Action for Minimal Residual
Disease) contains 22 tripple combinations of antibodies.
Best wishes
Anna Porwit-MacDonald, MD, PhD
Haematopathology Lab., Dept. of Pathology
Karolinska Hospital, Stockholm, Sweden
>
>


Home Page Table of Contents Sponsors E-Mail Archive Web Sites

CD-ROM Vol 3 was produced by Monica M. Shively and other staff at the Purdue University Cytometry Laboratories and distributed free of charge as an educational service to the cytometry community. If you have any comments please direct them to Dr. J. Paul Robinson, Professor & Director, PUCL, Purdue University, West Lafayette, IN 47907. Phone: (765)-494-0757; FAX(765) 494-0517; Web http://www.cyto.purdue.edu , EMAIL cdrom3@flowcyt.cyto.purdue.edu